(N)TSKCGECWOEU-CH
- Steuerleitungen
- 2XSLCHK-J LSOH VFD
- 2XSLCHK-J 3PLUS VFD
- 2XSLCY-J transparent/orange
2XSLCYK-J schwarz VFD - 2YSLCY-J / 2YSLCYK-J EMC + schwarz VFD
- 2YSLCYK-J 3 PLUS VFD SCHWARZ
- CY-JZ Grau
- FLEX-CY-JB/OB
- FLEX-CY-JZ POWER
- FLEX-CY-JZ/OZ
- Flex-JB gelb
- FLEX-JB/OB
- FLEX-JB/OB 450/750V
- FLEX-JZ POWER
- FLEX-JZ/OZ
- FLEX-SY-JB/OB
- FLEX-SY-JZ/OZ
- KÄLTEFLEX/ARCTIC FLEX - JZ
- PU gelb
- PU orange
- PU-CY
- PU-CY ohne Innenmantel
- PU-JZ
- Datenleitungen
- ES-BL-CY paarig
- ES-BL-CY-OZ
- ES-BL-OZ/JZ
- Li2YCY / Li2YCYV + schwarz
- LI2YCY-PIMF
- LIYCY
- LIYCY-CY paarig
- LIYCY-JB 0,6/1kV
- LIYCY-JZ
- LIYCY-TP paarig
- LIYCY-UL
- LIYCY-UL paarig
- LIYY
- LIYY paarig
- LIYY-UL
- RE2X(ST)H EN 50288-7
- RE2X(ST)Yv EN 50288-7
- RE2X(ST)Yv-PIMF EN 50288-7
- RE2Y(ST)Y EN 50288-7
- RE2Y(ST)Y-PIMF EN 50288-7
- Leitungen für den Schleppketteneinsatz
- EF Datenleitung
- EF-CY Datenleitung
- FLEX-EF
- Flex-EF EA
- FLEX-EF-CY
- Flex-EF-CY EA
- FLEX-PU-EF
- FLEX-PU-EF-CY
- INDRAMAT® Feedback
- INDRAMAT® Power
- Motorleitung für Fanuc-Systeme
- MULTIPLUS-CP
- MULTIPLUS-CP UL/CSA
- MULTIPLUS-P
- MULTIPLUS-P UL/CSA
- PU-EF (9Y11Y) EA
- PU-EF Datenleitung
- PU-EF-CP (9YC11Y) EA
- PU-EF-CP (TP) Datenleitung
- PU-EF-CP Datenleitung
- Siemens Servo Feedback
- Siemens Servo Power
- VDE approbierte Leitungen
- H03VVH2-F
- H05BQ-F, H07BQ-F schwarz
- H05BQ-F/H07BQ-F
- H05VV5-F (NYSLYO-J)
- H05VV5-F Multinorm
- H05VVC4V5-K (NYSLCYO-J)
- H05VVC4V5-K Multinorm
- Leitungen nach ausländischen Normen
- 2-Norm (UL/CSA)
- 2-Norm (UL/CSA-CY)
- AR2V
- AT-N05V3V3-F
- AT-N07V3V3-F
- BS 5308
- BS 5308 mit Gesamtschirm
- BS 5308 paarig geschirmt
- BS 5308 SWA mit Stahldrahtarmierung
- BS 5467 XLPE/PVC/AWA/PVC
- BS 5467 XLPE/PVC/SWA/PVC
- BS 6724 AWA Einzelader
- BS6724 unarmierte Einzelader
- BS6724 XLPE/LSZH/SWA/LSZH
- CEI 20-22 II
- DLO 2kV
- FG16M16/FG16OM16 0,6/1kV (früher FG7M1/FG70M1)
- FG16OH2R16 (früher FG7OH2R)
- FG16R16/FG16OR 16 0,6/1kV (früher FG7R/FG7OR)
- FROH2R
- FROR
- FS17 450/750V (früher N05V-K / N07V-K)
- Multinorm H05V2-K | H07V2-K
- RV-K 0.6/1 kV
- RZ1-K (AS)
- SJ
- SJOOW und SOOW
- SJT und SVT
- SJTO und STO
- SOOW
- TRAY
- TRAY CY
- Type W
- Type W Einzelader
- U-1000 R2V
- UL/CSA Style 1007/1569
- UL/CSA Style 1015
- UL/CSA Style 1430/1431
- Installationsleitungen und Einzeladern
- (N)YM(ST)-J
- ESUY
- ESY
- FLKF/LIFY
- FLRY
- H03VV-F
- H05V-K | H07V-K | LIY-V
- H05V-U/H07V-U
- H05V2-K | H07V2-K
- H05VV-F
- H07V-R
- NYM-O / NYM-J
- Ausgleichsleitungen und wärmebeständige Leitungen
- FEP
- FEP-Einzelader
- FZLSI
- H05SS-F
- N2GMH2G-J
- PTFE
- SID
- SIF
- SIF/GL
- SIFF
- SIFL/PVC flach
- SIFL/ZM1 flach
- SIHF-CU-SI mit Innenmantel
- SIHF-CU-SI schwarz
- SIHF-GLP
- SIHF-J
- SIHF-J schwarz
- SIHF/PVC rund
- SIHF/ZM1 rund
- Halogenfreie Leitungen
- (N)HXCH-FE 180 / E30
- (N)HXCH-FE 180 / E90
- (N)HXH-FE 180 / E30
- (N)HXH-FE 180 / E90
- FLEX-(ST)CH EMV
- Flex-CH
- FLEX-CH POWER
- FLEX-H
- FLEX-H POWER
- FLEX-H-JB
- H05Z-K und H07Z-K
- H07RN-F PREMIUM LSZH
- H07ZZ-F
- J-H(ST)H...Bd
- J-H(ST)H...Bd rot
- JE-H(ST)H...Bd E30
- JE-H(ST)H...BD E30 rot
- JE-H(ST)H...Bd E90
- JE-H(ST)H...Bd E90 rot
- JE-LiHCH
- LiHCH
- LiHCH (TP)
- LiHH
- N2XCH
- N2XH-O/-J
- NHXMH-J/O
- NSHXAFOU
- RD-H(St)H
- Flachleitungen, Liftkabel
- LIFT 2S
- LIFT 2S UL
- LIFT-H
- LIFT-S
- LIFT-S UL
- LSOH FLACH
- NEO-FLACH (NGFLGÖU)
- NEO-FLACH UL (NGFLGÖU UL)
- NEO-FLACH-CY / M(STD)HOU
- NEO-FLACH-CY UL
- PVC-FLACH (H05VVH6-F)
- PVC-FLACH (H07VVH6-F)
- PVC-FLACH UL
- PVC-FLACH-CY
- Schiffskabel
- FM2XCH
- FMGSGO
- FMSGSGO
- LMGSGO
- M2XH
- MGSGO
- MPRX
- MPRXCX
- RFOU
- TCX(C)
- Brandmeldekabel, Fernmeldekabel
- A-2Y(L)2Y...St III Bd.
- A-2YF(L)2Y...St III Bd.
- A-DQ(ZN)B2Y
- FIREFIT LIH(ST)H FE 180 PH 90
- FIREFIT LIH(ST)H-TP FE 180 PH 90
- FIREFIT LIH(ST)H-TP FE 180 PH 90 (Class 1)
- FIREFIT LIHH FE180/PH 90
- FIREFIT LIHH - TP FE180/PH 90
- FIREFIT LIHH - TP FE180/PH 90 (Class 1)
- I-Y(ST)Y Brandmeldekabel
- I-Y(ST)Y...Lg
- J-2Y(ST)Y...St III Bd
- J-YY...Bd
- JE-LIYCY...Bd Si
- JE-Y(ST)Y...Bd Si
- Starkstromkabel
- (N)2XCY FR
- (N)2XY FR
- N2XS(F)2Y
- N2XS2Y
- N2XSEY
- N2XSY
- NA2XS(F)2Y
- NA2XS2Y
- NA2XSY
- NAYCWY
- NAYY-J/O
- NYCWY
- NYCY
- NYY-O/-J
- Gummileitungen
- (N)SHTOU VS Gelb
- (N)TMCGCWÖU
- (N)TSCGEWOEU-F
- (N)TSCGEWOEU-R
- (N)TSCGEWOEU-SR
- (N)TSCGEWOEU-TR
- (N)TSCGEWÖU MT PLUS
- (N)TSKCGECWOEU-CH
- (N)TSKGECWOEU-FN
- H01N2-D / H01N2-E
- H05RN-F/H05RR-F
- H07BN4-F
- H07RN-F
- H07RN8-F
- NEOPREN / STN-J
- NSGAFÖU
- NSHTOU-J
- NSSHOU / 3E
- NSSHOU-O/-J
- NTSCGEWOEU-W/3
- NTSCGEWOEU-W/3E
- TML-O/-J
- Trommelflex PU-HF
- Ton- und Beleuchtungskabel
- SOFTFLEX-JB schwarz
- SOFTFLEX-JZ schwarz
- Koaxkabel, Busleitungen, Spiralkabel
- ASI-BUS PUR / TPE /EPDM
- BUS CAN
- BUS-EIB grün KNX
- BUS-EIB-H grün KNX
- BUS-LD
- BUS-LD PUR
- BUS-LEITUNG
- DEVICE NET THICK THIN
- DEVICE NET THICK THIN FRNC
- PA-BUS Schnellkontakt
- PA-BUS Schwarz/Blau
- Sondertypen
- FLEX-H-JB 450/750V
- 9YSLSTCYK-JB UL Black
- Control-CY-JZ UL Black 0,6/1kV
- Control-Y-JZ UL Black 0,6/1kV
- ES-BL-CY-OZ UV-beständig
- Flex (ST)H Cca
- Flex-CH POWER 0,6/1kV
- FQAR-PG 150/250V
- FQLQ 450/750V
- Hybrid Ladekabel
- Kabeltec-Battery BQ-F
- KTECtherm 125
- L2 BUS FC LSOH
- LIH(ST)H-F (TP/TT)
- NYRY
- PA-BUS FC halogenfrei
- Profibus DP-ET 200C
- S05VV5-F UL/CSA schwarz
- THHW MTW UL HAR
- YSLY-O UL Black Ul/CSA
- Systemlösungen
- Solar
- SOLAR H1Z2Z2-K TÜV/CE
(N)TSKCGECWOEU-CH
Medium voltage, flexible power supply coal cutter cable for chain operation.
Verwendung
Flexible power supply cable for use in underground mining facilities for mobile machines like coal cutter etc. Designed for use in cable chains trailed behind the machines. Chains have proective function and absorb the tensile forces occuring during operation.
[INDEX:20201001SQ]
Aufbau
- Control/protective conductor: Spirally applied concentric CuSn wires forming control conductors around support element, EPR insulation and spirally applied concentric CuSn wires to form protective conductor.- Electrical field control: Inner and outer layers of semiconductive rubber
- Core arrangement: Three power conductors laid-up with double concentric control/protective conductor elemnts in the outer interstices, with optimised lay length.
- Signal/monitoring conductor: Spirally applied FeZn and CuSn wires in a vulcanized bond between inne rand outer sheath.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
Kabel
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|