(N)HXH-FE 180 / E90
- Steuerleitungen
- 2XSLCHK-J LSOH VFD
- 2XSLCHK-J 3PLUS VFD
- 2XSLCY-J transparent/orange
2XSLCYK-J schwarz VFD - 2YSLCY-J / 2YSLCYK-J EMC + schwarz VFD
- 2YSLCYK-J 3 PLUS VFD SCHWARZ
- CY-JZ Grau
- FLEX-CY-JB/OB
- FLEX-CY-JZ POWER
- FLEX-CY-JZ/OZ
- Flex-JB gelb
- FLEX-JB/OB
- FLEX-JB/OB 450/750V
- FLEX-JZ POWER
- FLEX-JZ/OZ
- FLEX-SY-JB/OB
- FLEX-SY-JZ/OZ
- KÄLTEFLEX/ARCTIC FLEX - JZ
- PU gelb
- PU orange
- PU-CY
- PU-CY ohne Innenmantel
- PU-JZ
- Datenleitungen
- ES-BL-CY paarig
- ES-BL-CY-OZ
- ES-BL-OZ/JZ
- Li2YCY / Li2YCYV + schwarz
- LI2YCY-PIMF
- LIYCY
- LIYCY-CY paarig
- LIYCY-JB 0,6/1kV
- LIYCY-JZ
- LIYCY-TP paarig
- LIYCY-UL
- LIYCY-UL paarig
- LIYY
- LIYY paarig
- LIYY-UL
- RE2X(ST)H EN 50288-7
- RE2X(ST)Yv EN 50288-7
- RE2X(ST)Yv-PIMF EN 50288-7
- RE2Y(ST)Y EN 50288-7
- RE2Y(ST)Y-PIMF EN 50288-7
- Leitungen für den Schleppketteneinsatz
- EF Datenleitung
- EF-CY Datenleitung
- FLEX-EF
- Flex-EF EA
- FLEX-EF-CY
- Flex-EF-CY EA
- FLEX-PU-EF
- FLEX-PU-EF-CY
- INDRAMAT® Feedback
- INDRAMAT® Power
- Motorleitung für Fanuc-Systeme
- MULTIPLUS-CP
- MULTIPLUS-CP UL/CSA
- MULTIPLUS-P
- MULTIPLUS-P UL/CSA
- PU-EF (9Y11Y) EA
- PU-EF Datenleitung
- PU-EF-CP (9YC11Y) EA
- PU-EF-CP (TP) Datenleitung
- PU-EF-CP Datenleitung
- Siemens Servo Feedback
- Siemens Servo Power
- VDE approbierte Leitungen
- H03VVH2-F
- H05BQ-F, H07BQ-F schwarz
- H05BQ-F/H07BQ-F
- H05VV5-F (NYSLYO-J)
- H05VV5-F Multinorm
- H05VVC4V5-K (NYSLCYO-J)
- H05VVC4V5-K Multinorm
- Leitungen nach ausländischen Normen
- 2-Norm (UL/CSA)
- 2-Norm (UL/CSA-CY)
- AR2V
- AT-N05V3V3-F
- AT-N07V3V3-F
- BS 5308
- BS 5308 mit Gesamtschirm
- BS 5308 paarig geschirmt
- BS 5308 SWA mit Stahldrahtarmierung
- BS 5467 XLPE/PVC/AWA/PVC
- BS 5467 XLPE/PVC/SWA/PVC
- BS 6724 AWA Einzelader
- BS6724 unarmierte Einzelader
- BS6724 XLPE/LSZH/SWA/LSZH
- CEI 20-22 II
- DLO 2kV
- FG16M16/FG16OM16 0,6/1kV (früher FG7M1/FG70M1)
- FG16OH2R16 (früher FG7OH2R)
- FG16R16/FG16OR 16 0,6/1kV (früher FG7R/FG7OR)
- FROH2R
- FROR
- FS17 450/750V (früher N05V-K / N07V-K)
- Multinorm H05V2-K | H07V2-K
- RV-K 0.6/1 kV
- RZ1-K (AS)
- SJ
- SJOOW und SOOW
- SJT und SVT
- SJTO und STO
- SOOW
- TRAY
- TRAY CY
- Type W
- Type W Einzelader
- U-1000 R2V
- UL/CSA Style 1007/1569
- UL/CSA Style 1015
- UL/CSA Style 1430/1431
- Installationsleitungen und Einzeladern
- (N)YM(ST)-J
- ESUY
- ESY
- FLKF/LIFY
- FLRY
- H03VV-F
- H05V-K | H07V-K | LIY-V
- H05V-U/H07V-U
- H05V2-K | H07V2-K
- H05VV-F
- H07V-R
- NYM-O / NYM-J
- Ausgleichsleitungen und wärmebeständige Leitungen
- FEP
- FEP-Einzelader
- FZLSI
- H05SS-F
- N2GMH2G-J
- PTFE
- SID
- SIF
- SIF/GL
- SIFF
- SIFL/PVC flach
- SIFL/ZM1 flach
- SIHF-CU-SI mit Innenmantel
- SIHF-CU-SI schwarz
- SIHF-GLP
- SIHF-J
- SIHF-J schwarz
- SIHF/PVC rund
- SIHF/ZM1 rund
- Halogenfreie Leitungen
- (N)HXCH-FE 180 / E30
- (N)HXCH-FE 180 / E90
- (N)HXH-FE 180 / E30
- (N)HXH-FE 180 / E90
- FLEX-(ST)CH EMV
- Flex-CH
- FLEX-CH POWER
- FLEX-H
- FLEX-H POWER
- FLEX-H-JB
- H05Z-K und H07Z-K
- H07RN-F PREMIUM LSZH
- H07ZZ-F
- J-H(ST)H...Bd
- J-H(ST)H...Bd rot
- JE-H(ST)H...Bd E30
- JE-H(ST)H...BD E30 rot
- JE-H(ST)H...Bd E90
- JE-H(ST)H...Bd E90 rot
- JE-LiHCH
- LiHCH
- LiHCH (TP)
- LiHH
- N2XCH
- N2XH-O/-J
- NHXMH-J/O
- NSHXAFOU
- RD-H(St)H
- Flachleitungen, Liftkabel
- LIFT 2S
- LIFT 2S UL
- LIFT-H
- LIFT-S
- LIFT-S UL
- LSOH FLACH
- NEO-FLACH (NGFLGÖU)
- NEO-FLACH UL (NGFLGÖU UL)
- NEO-FLACH-CY / M(STD)HOU
- NEO-FLACH-CY UL
- PVC-FLACH (H05VVH6-F)
- PVC-FLACH (H07VVH6-F)
- PVC-FLACH UL
- PVC-FLACH-CY
- Schiffskabel
- FM2XCH
- FMGSGO
- FMSGSGO
- LMGSGO
- M2XH
- MGSGO
- MPRX
- MPRXCX
- RFOU
- TCX(C)
- Brandmeldekabel, Fernmeldekabel
- A-2Y(L)2Y...St III Bd.
- A-2YF(L)2Y...St III Bd.
- A-DQ(ZN)B2Y
- FIREFIT LIH(ST)H FE 180 PH 90
- FIREFIT LIH(ST)H-TP FE 180 PH 90
- FIREFIT LIH(ST)H-TP FE 180 PH 90 (Class 1)
- FIREFIT LIHH FE180/PH 90
- FIREFIT LIHH - TP FE180/PH 90
- FIREFIT LIHH - TP FE180/PH 90 (Class 1)
- I-Y(ST)Y Brandmeldekabel
- I-Y(ST)Y...Lg
- J-2Y(ST)Y...St III Bd
- J-YY...Bd
- JE-LIYCY...Bd Si
- JE-Y(ST)Y...Bd Si
- Starkstromkabel
- (N)2XCY FR
- (N)2XY FR
- N2XS(F)2Y
- N2XS2Y
- N2XSEY
- N2XSY
- NA2XS(F)2Y
- NA2XS2Y
- NA2XSY
- NAYCWY
- NAYY-J/O
- NYCWY
- NYCY
- NYY-O/-J
- Gummileitungen
- (N)SHTOU VS Gelb
- (N)TMCGCWÖU
- (N)TSCGEWOEU-F
- (N)TSCGEWOEU-R
- (N)TSCGEWOEU-SR
- (N)TSCGEWOEU-TR
- (N)TSCGEWÖU MT PLUS
- (N)TSKCGECWOEU-CH
- (N)TSKGECWOEU-FN
- H01N2-D / H01N2-E
- H05RN-F/H05RR-F
- H07BN4-F
- H07RN-F
- H07RN8-F
- NEOPREN / STN-J
- NSGAFÖU
- NSHTOU-J
- NSSHOU / 3E
- NSSHOU-O/-J
- NTSCGEWOEU-W/3
- NTSCGEWOEU-W/3E
- TML-O/-J
- Trommelflex PU-HF
- Ton- und Beleuchtungskabel
- SOFTFLEX-JB schwarz
- SOFTFLEX-JZ schwarz
- Koaxkabel, Busleitungen, Spiralkabel
- ASI-BUS PUR / TPE /EPDM
- BUS CAN
- BUS-EIB grün KNX
- BUS-EIB-H grün KNX
- BUS-LD
- BUS-LD PUR
- BUS-LEITUNG
- DEVICE NET THICK THIN
- DEVICE NET THICK THIN FRNC
- PA-BUS Schnellkontakt
- PA-BUS Schwarz/Blau
- Sondertypen
- FLEX-H-JB 450/750V
- 9YSLSTCYK-JB UL Black
- Control-CY-JZ UL Black 0,6/1kV
- Control-Y-JZ UL Black 0,6/1kV
- ES-BL-CY-OZ UV-beständig
- Flex (ST)H Cca
- Flex-CH POWER 0,6/1kV
- FQAR-PG 150/250V
- FQLQ 450/750V
- Hybrid Ladekabel
- Kabeltec-Battery BQ-F
- KTECtherm 125
- L2 BUS FC LSOH
- LIH(ST)H-F (TP/TT)
- NYRY
- PA-BUS FC halogenfrei
- Profibus DP-ET 200C
- S05VV5-F UL/CSA schwarz
- THHW MTW UL HAR
- YSLY-O UL Black Ul/CSA
- Systemlösungen
- Solar
- SOLAR H1Z2Z2-K TÜV/CE
(N)HXH-FE 180 / E90
Halogenfreie Starkstromkabel mit 90 Min. Funktionserhalt
Verwendung
Halogenfreie Erdkabel werden eingesetzt wo Schutz an Menschen oder hohen Sachwerten erforderlich ist z.B. Schulen, Hotels, Krankenhäuser, Tunnels, etc. Aufgrund des Funktionserhalts und der geringen Bildung toxischer Gase sichert dieses Kabel den Erhalt der Funktionalität im Brandfall von Beleuchtung, Lüftung, Notrufsysteme, etc.
Geeignet zur festen Installation in trockenen Räumen und im Freien, jedoch nicht direkt in der Erde oder im Wasser.
[INDEX:20201001SQ]
Aufbau
- CU-Leiter blank, eindrähtig, mehrdrähtig- flammwidrig nach IEC 60332-1-2
- Aderisolation aus halogenfreien Polymer nach VDE 207
- Aderkennzeichnung farbig nach VDE 0293
- Schutzleiter grün/gelb
- Adern gemeinsam verseilt
- Außenmantel aus halogenfreier Polymer-Mischung orange
- Biegeradius 15 x Ø
Prüfungen:
- Brandprüfung nach VDE 0472 Teil 804 Prüfart C, IEC 60332-3 und HD 405.3
- Korrosivität von Brandgasen nach VDE 0472 Teil 813, IEC 60754-2 und HD 602
- Halogenfreiheit nach VDE 0472 Teil 815 und IEC 60754-1
- Rauchdichte nach VDE 0472 Teil 816, Prüfart C, IEC 61034-1/61034-2, HD 606 und BS 7622 Teil 1 und 2
- Isolationserhalt bei Flammeinwirkung nach VDE 0472 Teil 814 » IEC 60331-1-2
- Funktionserhalt von Kabelanlagen nach DIN 4102 Teil 12 (90 min)
RE: runder Leiter eindrähtig
RM: runder Leiter mehrdrähtig
SM: sektorförmiger Leiter
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
Kabel
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|